FORD SCORPIO

1985-1994 of release

Repair and car operation



Ford Skorpio
+ 1.1. Car identification
+ 2. Maintenance service
+ 3. Engines
+ 4. Cooling system
- 5. Fuel system
   5.1. A technical characteristics
   5.2. Fuel
   5.3. Neetilirovannyj gasoline of engines V6, 2.4 and 2.9 дм3
   + 5.4. System of giving of air
   + 5.5. Carburettor PIERBURG
   + 5.6. Carburettor WEBER 2V
   + 5.7. Carburettor WEBER 2V TLD
   - 5.8. System of injection of fuel
      5.8.1. Adjustment of turns of idling and quality of a mix
      5.8.2. Removal and installation of the gauge of position throttle заслонки
      5.8.3. Removal and installation of the valve of management by idling turns
      5.8.4. Removal and installation of measuring instruments of a stream of air
      5.8.5. Removal and installation of fuel atomizers
      5.8.6. Removal and installation of the temperature gauge of a fuel highway
      5.8.7. Removal and installation of a regulator of pressure of fuel
      5.8.8. Removal and installation of the case throttle заслонки on engine DOHC
      5.8.9. Removal and installation of the oxygen gauge (HEGO)
      5.8.10. Removal and installation of a coal adsorber
      5.8.11. Removal and installation of the electromagnetic valve of a coal adsorber
   5.9. Removal and installation of an inlet collector
+ 6. Coupling
+ 7. Transmissions
+ 8. A kardannyj shaft and the back bridge
+ 9. A steering
+ 10. Suspension brackets
+ 11. Brake system
+ 12. Wheels and tyres
+ 13. A body
+ 14. An electric equipment


b087f616

5.8.4. Removal and installation of measuring instruments of a stream of air
THE GENERAL DATA

Position of an inlet air route and collar of its fastening


On engines V6 two measuring instruments of a stream of air are established.

PERFORMANCE ORDER
1. To remove a wire of weight from the accumulator.
2. To release a lock clip and to remove a socket (it is specified by an arrow) from a measuring instrument.
3. To weaken a collar and to disconnect from a measuring instrument an air route.
4. To release from clips and to remove together with a measuring instrument a cover of the air filter.
5. To unscrew four bolts of fastening and to separate a measuring instrument of a stream of air from a cover.
6. Installation is made in sequence, return to removal. To check up the maintenance WITH.